ONH-2000
Oxygen / Nitrogen / Hydrogen Determinator

  Specifications
ON operation OH operation
MEASURING RANGES

Oxygen at 1 gram sample

Oxygen at 1 gram sample

Low Oxygen
0.0 - 300 ppm1)

High Oxygen
up to 2%1)

Low Oxygen
0.0 - 300 ppm1)

High Oxygen
up to 2%1)

Sensitivity : 0.01 ppm Oxygen
Indicating range: 0 - 100% Oxygen2)

Sensitivity : 0.01 ppm Oxygen
Indicating range: 0 - 100% Oxygen2)

Nitrogen at 1 gram sample

Hydrogen at 1 gram sample

Low Nitrogen
0.0 - 300 ppm1)

High Nitrogen
up to 2%1)

Low Hydrogen
0.0 - 50 ppm1)

High Hydrogen
up to 1000 ppm1)

Sensitivity: 0.1 ppm Nitrogen
Indication range: 0 - 100% Nitrogen2)

Sensitivity: 0.01 ppm Hydrogen
Indication range: 0 - 100% Hydrogen2)

ACCURACY

Low Oxygen
±0.1 ppm or ±1% of Oxygen present

Low Oxygen
±0.1 ppm or ±1% of Oxygen present

High Oxygen
±2 ppm or ±1% of Oxygen present

High Oxygen
±2 ppm or ±1% of Oxygen present

Low Nitrogen
±0.1 ppm or ±1% of Nitrogen present

Low Hydrogen
±0.05 ppm or ±1% of present Hydrogen

High Nitrogen
±2 ppm or ±1% of Nitrogen present

High Hydrogen
±0.5 ppm or ±1% of present Hydrogen

GENERAL SPECIFICATIONS

Detection method
Solid State infrared absorption for Oxygen and thermal conductivity for Hydrogen and Nitrogen

Normal sample weight
1 gram

Normal analysis time
2 minutes

Chemicals
C2O Trap - Sodium Hydroxide / H2O Trap - Magnesium Perchlorate / Catalyst - Copper Oxide / Schutzes Reagent

Calibration
Standard samples and gas dosing device on request

Furnace temperature: up to 3000°C
Furnace power: 0 to 8 kW

Gas required
Nitrogen at least 99.995% pure3) 2 to 4 bar (30 to 60 psi) / Helium at least 99.995% pure3) 2 to 4 bar (30 to 60 psi)

Compressed air
2 bar (30 psi)

Interfaces
Computer - serial4)

Power requirements
max 8500 Watts, 400 V AC ±10% 50/60 Hz 3 phase and neutral or 230 V AC ± 10% 50/60 Hz single phase on request

Dimensions               Width              Height               Depth                       
                  55 cm (21")     80 cm (31.5")  60 cm (23.5")

Weight
approx. 140 kg

ACCESSORIES

Balance: 0.0001g to 60 g ± 0.0001 g

Computer: PC with HDD, 3.5" drive, CD-ROM, TFT flat screen and keyboard

Color printer with automatic cut sheet feed, other options on request

  1) Other ranges on request.  2) Possible by reducing the sample weight.  3) 99.999% pure for low oxygen analysis. 4) Balance (serial) and printer (USB, parallel) are connected to the PC.